video
Barrier Gate Operator
automatic gate barrier
Road Barrier Gate System
1/2
<< /span>
>

Barrier Gate Operator

Barrier Gate Operator(customized) Instruction Barrier Gate Operator Function 1. Automatic travel learning: after powering on, barrier gate operator will learn the travel automatically, to slowly open in place first, then to slowly close in place, after which the travel learning is complete. The...

Add To Inquiry

Barrier Gate Operator(customized) Instruction 

Metal bariier gate



Barrier Gate Operator Function 

1. Automatic travel learning: after powering on, barrier gate operator will learn the travel automatically, to slowly open in place first, then to slowly close in place, after which the travel learning is complete. The boom will be in its vertical position as final state.

 

2. Open/Close function: connect Open signal port to +24V to send Open signal; connect Close signal port to +24V to send Close signal. If fleet counting mode is not required, please connect to +24V and remote control open signal for opening; connect to +24V and remote control close signal for closing.

 

3. Remote control open/close signal function: The control board is inserted with external receiver and 2 remote controls have already been equipped, press OPEN to lift the boom, press CLOSE to drop the boom. Please refer to the remote control drawing.

 

4. Anti-smashing signal function: connect external anti-smashing equipment signal to +24V infrared anti-smashing signal terminal, the boom will up if the signal is detected during the closing process.

 

5. Loop detector function: To connect with loop detector, please connect the 2 signal output wires to +12V terminal and loop detector terminal first, after correctly wiring, every vehicle passing through will be detected by the loop detector, and the barrier boom will automatically drop to close.

 

6. Fire alarm input signal/Emergent stop input signal: This signal has the highest priority. Barrier gate will emergently stop under emergency condition. The boom will be automatically reset (travel learning) after removing this signal.

 

7. Boom swing out signal: connect this signal to the boom swing out signal input port, after detecting this signal, the control board will alarm. After removing this signal and being re-powered, the boom will be operated normally.

 

8. Delay closed function: No.5-8 on Dip switch 2 are for it. The boom will automatically close in the settled delaying time after opening in place. This function will be reset once the infrared or other anti-smashing signals are detected. 

 

 