PY600-B Board
1.110V/220V AC 2.PCB BOARD MATERIAL -- FR-4. COMPATIBILITY--The control board is only compatible with our remote control. You can ask us before you make an order. 3.AUTOMATIC CLOSE TIME SETTING--12s, 24s, 36s. 4.REMOTE CONTROL--For this control board,you can add 40 remote controls.(if you need the remote control,you can choose it from our store.) 5.EASY TO INSTALL AND SETUP--You can install and setup by yourself according to the instructions easily.
Number | Function | Description |
1 | Soft Start/Close Function | OFF–enabled ON–disabled Default position is OFF. |
2 | Limit Switch Setting | OFF–Normal Open ON–Normal Close Default position is ON, this should align with limit switch and is not recommended to be modified by the users. |
3
| Automatic Close Time Setting | Automatic close time setting: the gate is operated to open by remote control operation and will close automatically after a few seconds delay. 3 OFF 4 ON: automatic close delay time is 12s. 3 ON 4 OFF: automatic close delay time is 24s. 3 ON 4 ON: automatic close delay time is 36s. 3 OFF 4 OFF: no automatic close function. Default setting: 3 OFF 4 OFF Disable the automatic close function. |
4
| ||
5 | Auto-reverse Function | OFF-enable ON-disable Default position is OFF, this should align with the opener status and is not recommended to be modified by the users. |
6 | Remote Control Mode Switch | OFF-four channel mode ON-single channel mode |

VR1: Stall Force
Mode Maximum = More Force = Less sensitive
Minimum = Less Force = More sensitive
When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate opener will detect obstacles and impacts to the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise to decrease.
For safety, we strongly recommend that Stall Force Mode is left enabled (Dip switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position.
VR2: Brake Force Adjustment For adjusting brake force at the limit position during gate opening and closing. This should only be adjusted for heavy gates that need additional force to brake when limit switch is detected. Rotate VR2 clockwise to increase, counter-clockwise to decrease. Default setting is at minimum.
VR3: Slow Start/Stop Width Adjustment This switch controls how many seconds the gate opener operates at maximum speed. Rotate VR3 clockwise to increase, rotate counter-clockwise to reduce. When VR3 switches to minimum, slow start/stop function is disable.
VR4: Motor Output Force Adjustment For best performance, set the torque at the lowest setting for secure use. Rotate clockwise to increase, counter-clockwise to decrease. Default setting is at maximum
Our Service
Backed by a 12-month warranty, and free product return & exchange service within 30 days.
We are always dedicated to providing customers with good quality products.
We provide the excellent customer service and try our best to solve your problems.
How can I place an order?
The product is in stock: Please make an order directly on this page.
The product is out of stock: Please contact the customer service for the product stock information.
Need a customized product: Please contact the customer service and we will give you a quotation.
Send Inquiry