Ways To Deal With Routine Problems Of Barrier Gates

Sep 09, 2022

1. In the normal state of the gate, the drop bar is higher or lower than the horizontal position. If the drop bar of the barrier gate is higher than the horizontal position, first check whether the lower limit switch controlled by the drop bar is loose. If it is loose, tighten the lower limit screw; Whether the barrier rail is shortened and folded, the length of the tension spring can be adjusted by fine-tuning the screw sleeve; readjust the barrier to the horizontal position and tighten the screws. If it is lower than the horizontal position, check whether the limit switch screw is loose, check whether the railing is loaded with heavy objects and garbage, the worm gear of the gate gate motor is worn and the self-locking performance is deteriorated, the limit function is invalid, tidy up the railing, adjust the screw sleeve, and replace the turbine. Worm, readjust the correct orientation, and tighten the screws. 2. The gate receives the signal and cannot complete the action normally. This situation is often encountered. After the gate receives the signal, either it will not operate, or it may not be reset after operation, and if a signal is given, it will act for a while, and so on. Normal gate lift action. Do several times of dropping and lifting signals to the gate to reset the gate, check the DIP switch behind the gate, reset the DIP switch, and adjust it to normal use; check whether the motor is stuck In case of damage, maintain or replace the motor; check the electrical and electronic components according to the electrical drawings of the gate, and replace and deal with electrically damaged circuit boards, capacitors, and wires.