video
Control Board
DKC500DC Control Board
gate opener controller-dkc500dc
1/2
<< /span>
>

Gate Opener DKC500DC Controller

Work for DKC500DC(L) and DKC800DC(L) sliding gate openers,the control board is 24VDC, compatible with 24V DC sliding motors, there are 8 dip switch to adjust.

Add To Inquiry

gate controller

 

Wiring instruction:

J1 Terminal

5 COM (GND)

6 Photocell input (N.C.);

7 Extra power input +24VDC

 

J2 Terminal

Connect to 24VAC(Fig.11 shows 120W 230VAC/24VAC annular transformer connection)

 

BAT+ Terminal

Battery interface

 

J4 Terminal

DC motor wire connection (Red wire to top, black wire to bottom)

 

J7 Terminal

1 Gate open control button (N.O.);

2 Gate close control button (N.O.);

3 Stop control button (N.O.);

4 Control button common terminal;

 

J8 Terminal

24V DC caution light

 

J10 Terminal

OP Open limit switch;

COM Limit switch common terminal;

CL Close limit switch;

 

DIP SWITCH

Work for DKC500DC(L) and DKC800DC(L) sliding gate openers,the control board is 24VDC, compatible with 24V DC sliding motors, there are 8 dip switch to adjust.

 

serial number


1

2

1 ON 2 OFF: automatic close delay time is 3s.

1 OFF 2 ON: automatic close delay time is 10s.

1 ON 2 ON: automatic close delay time is 30s.

1 OFF 2 OFF: cancel automatic close function.

3

ON - Remote control is three button mode, the first button is OPEN, the second button is CLOSE, the third button is STOP.

OFF- Remote control is single button mode, one same button on the remote control to circularly control OPEN/STOP/CLOSE/STOP.

4

OFF - External button switch is single button mode, connect to 1 and 4 of J7.

ON - External button switch is three button mode.

5

 

Left and Right installation setting.

OFF - Right side mounting

ON - Left side mounting

The change of door close direction will be valid only after the re-power.

6

Limit switch setting.

ON - Normal open (N.O.);

OFF - Normal close (N.C.).

7

Meet obstacle reversal function.

ON - enabled;

OFF - disabled.

8

Infrared detection delay when closing

ON - infrared detection delay is 1 second;

OFF - infrared detection delay function is disabled.

 

 

 

 


Send Inquiry

(0/10)

clearall